2-6.
Mechanical
Alignment
of
Track
#1
Stop
2-6-1.
General
This
procedure
adjusts
the
Track
#1
Stop.
The
Track
#1
Stop
is
used
by
the
computer
in
the
VIC-1541
for
only
two
purposes:
1.
Formatting
a
blank
floppy
disk
("New"
command).
2.
Soft
error
recovery.
The
procedure
that
follows
should
only
be
used
after
carefully
verifying
that
the
rest
of
the
VIC-1541
is
properly
operating.
(Complete
coverage
of
proper
operation
is
given
in
Troubleshooting-Part
2,
in
the
1541
Maintenance
Manual.)
2-6-2.
Preparation
for
Mechanical
Alignment
(Detailed
disassembly/assembly
instructions
can
be
found
in
the
1541
Maintenance
Manual.)
1.
Remove
all
external
cables
from
VIC-1541.
2.
Remove
upper
cover.
3.
Remove
RFI
Shield.
4.
Remove
Disk
Controller
PC
Board.
5.
Remove
Drive
Unit.
6.
Reconnect
Jl
to
PI,
J2
to
P2,
J5
to
P5,
J6
to
P6
and
J7
to P7
in
such
a
manner
that
access
is
still
allowed
to
the
Track
#1
Stop
adjustment.
(See
Figure
2-3)
(CAUTION
1
•
DO
NOT
ALLOW
PATHWORK
ON DISK
CONTROLLER
PC
BOARD
TO
CONTACT
THE
FRAME
OR
DRIVE
UNIT
ASSEMBLIES.
USE
AN
INSULATING
RUBBER
MAT,
IF
NECESSARY,
TO
INSULATE
THE
DISK
CONTROLLER
PC
BOARD
FROM
THESE
ASSEMBLIES.
2-6-3.
Mechanical
Alignment
1.
Connect
serial
bus
cable
between
P3
and
VIC-20/COMMODORE
64.