Section
2-CALIBRATION
2-1.
General
This
section
contains
step-by-step
procedures
for
calibrating
the
VIC-1541.
Only
one
calibration
adjustment,
to
adjust
the
speed
of
the
disk
to
300
rpm,
is
provided
in
the
VIC-1541.
Perform
the
calibration
procedure
at
the
following
intervals:
1.
Every
6
months.
2.
During
the
process
of
troubleshooting.
3.
After
a
repair
action.
2-2.
Equipment
Required
1.
Small
slotted
screwdriver
2.
Phillips
screwdriver
3.
Timing
light
(Refer
to
Appendix
B)
#
Any
strobe
light
with
an
accurate
frequency
of
50
Hz
(+/-
1%)
or
60
Hz
(+/-
1%)
may
be
used
in
place
of
the
timing
light.
4.
Blank
floppy
disk
(5
1/4
inch,
single
sided)
2-3.
Preparation
for
calibration
(Detailed
disassembly/assembly
instructions
can
be
found
in
the
1541
Maintenance
Manual.)
1.
Remove
top
cover.
2.
Remove
RFI
shield.
3.
Disconnect
P8
from
J8.
4.
Reinstall
RFI
shield.
5.
Remove
bottom
cover.
6.
Place
disk drive
on
left-hand
side.
Use
a
thin book
or
magazine
to
prop
up
drive.
(Refer
to
Figure
2-1).
Page
2-1
Zobrazit stránku 11