Commodore 1541-II Uživatelská příručka Strana 13

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 64
  • Tabulka s obsahem
  • ŘEŠENÍ PROBLÉMŮ
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 12
ACCESS
HOLE
FOR
VR1
TIMING
DISK
2-4,
60
Hz
TIMING
MARKS
50
Hz
TIMING
MARKS
Figure
2-1.
Calibration
VIC-1541
Prepared
for
Calibration
1.
Connect
VIC-20/COMMODORE
64
to
video
monitor
or
TV.
(Refer
to
computer
User's
Guide
for
proper
connection.)
2.
Connect
serial
bus
cable
between
P3
on
VIC-1541
and
serial
bus
connector
on
VIC-20/COMMODORE
64.
3.
Connect
AC
power
cord
between
J9
on
VIC-1541
and
AC
outlet.
I
warningI
USE
EXTREME
CARE
TO
AVOID
CONTACT
WITH
FRAME
COMPONENTS.
HIGH
AC
VOLTAGE
POTENTIALS
ARE
PRESENT
DURING
CALIBRATION. THESE
VOLTAGE
POTENTIALS
CAN
CAUSE
BODILY
INJURY
OR
DEATH.
4.
Place
VIC-1541
power
switch
to
ON.
5.
Apply
power
to
VIC-20/
COMMODORE
64.
6.
If
a
VIC-20
is
the
computer
being
used,
enter
the
following
command:
OPEN
15,8,15,"UI-":CLOSE
15<Return>
7.
Insert
blank
floppy
disk
into
VIC-1541.
8.
Plug timing
strobe
light into
AC
outlet.
Position
light
near
timing
disk
(Refer
to
Figure
2-1).
9.
Enter
following
command
into
VIC-20/COMMODORE
64:
OPEN
15,8,15,"NO:CAL,01":CLOSE
15
<Return>
Page
2-2
Zobrazit stránku 12